W-139: 3-Stage S.S. Washer

  • Mfg: Advanced Curing Systems
  • Opening: 3’6” wide x 6’4” high
  • Line Speed: 5 fpm (Can be increased)
  • All Stainless Steel Construction
  • Kerr Pumps
  • Insulated Heated Tanks
  • Maxon Tube-O-Therm Burners
  • Honeywell/AB Controls
  • 60 Amps 480V/3-Phase/60 Hz
  • Natural Gas or Propane

WASHER SPECIFICATIONS

Stage

Length

Operation Temperature

Time at  5 FPM

Sets of risers per side

Nozzles
Per Stage

Entrance

7’

Stage 1 (Clean)

5’

104-140 F

60

6

84

Drain

9’-6”

Stage 2 (Rinse)

3”

Ambient

36

4

56

Drain

9’

Stage 3 (Seal)

3’

104-140 F

36

4

56

Exit

6’-6”

Total Length

43’

Stage

Pump GPM

Tank Capacity

Nozzle GPM

Pump TDH

Pump HP

Gross BTU/hr

Stage 1 (Clean)

300

1125

3.0

50

7.5

2,000,000

Stage 2 (Rinse)

200

675

3.0

50

5

Stage 3 (Seal)

200

675

3.0

55

5

900,000